Proline Promag L 400
Electromagnetic flowmeter
Flowmeter for the water and wastewater industry with a weight-optimized sensor
The weight-optimized Promag L is suitable for applications in the water and wastewater industry. Due to its lap-joint flange concept, the flowmeter offers flexible and easy installation. Promag L 400 saves time and costs thanks to the broad functionality of its water- and wastewater-optimized transmitter. In addition, Heartbeat Technology ensures compliance and process safety at all times.
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s) -
Measuring range
9 dm³/min to 162 000 m³/h (2.5 gal/min to 1030 Mgal/d)
-
Medium temperature range
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F) -
Max. process pressure
PN 16, Class 150
-
Wetted materials
Liner: PTFE; Polyurethane; Hard rubber
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
-
Quick selection
Individual configuration
-
Benefits
Reduced installation costs – flexible mounting by lap-joint flange concept (DN < 350/14")
Energy-saving flow measurement – no pressure loss due to cross-section constriction
Maintenance-free – no moving parts
Safe operation – no need to open the device due...
-
Field of application
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
Suitable for applications in the water and wastewater industry.
Device properties
Up to 30% less sensor weight
Nominal diameter: DN 25 to...
Documents / Manuals / Software
-
Proline Promag L 400
Technical Information
Electromagnetic flowmeter
Weight-optimized sensor with a state‐of‐the‐art transmitter for Water
& WastewaterTechnical Information (TI) -
Proline Promag L 400
HART
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag L 400
Modbus RS485
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag L 400
PROFIBUS DP
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag L 400
EtherNet/IP
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag 400
Modbus RS485
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 400
HART
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 400
PROFIBUS DP
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 400
EtherNet/IP
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag
Brief Operating Instructions
Proline Promag
Part 1 of 2
Electromagnetic sensorShort Instruction (KA)04/17English -
Flow device
Proline 400
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Flow device
Proline 400
Brief Operating Instructions
HART transmitter
with electromagnetic sensorShort Instruction (KA)02/19English -
Flow device
Proline 400
Brief Operating Instructions
Modbus RS485 transmitter
with electromagnetic sensorShort Instruction (KA)02/19English -
Flow device
Proline 400
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19English -
Proline Promag L
Brief Operating Instructions
Proline Promag L
Electromagnetic sensorShort Instruction (KA)02/18English -
Proline Promag L 400
Brief Operating Instructions
Electromagnetic flowmeter
Short Instruction (KA)02/18English -
Replacing Spare Parts
Promag, Promass 100, CNG-, LNG-, LPGmass, Promag 400 Index C, Proline
300, 500, 500-digital, Prosonic Flow E 100, Prosonic Flow E He
at, Prosonic Flow, t-mass 300, 500-digitalInstallation Instructions (EA) -
Replacing the sensor
Promag 400 Index C
Installation Instructions (EA) -
Replacing the transmitter
Promag 400 Index C
Installation Instructions (EA) -
Pipe Mounting Set
Installation Instructions
Promag 400 Index C
Installation Instructions (EA) -
Replacing the Display Protection
Promag 400 Index C, Promag, Promass, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Replacing Small parts
Promag, Promass 100, 500, CNG-, LNG-, LPGmass, Promag 400 Index C,
Prosonic Flow E 100, Prosonic Flow E Heat, Prosonic Flow, t-mass
500-digitalInstallation Instructions (EA) -
Replacing the Display module
Promag 400 Index C
Installation Instructions (EA) -
Converting the Transmitter
Promag 50, 53 W, L , Promag W, L 400 Index C
Installation Instructions (EA) -
Replacing Small Parts
Promag 400 , Promag 800 Index B, Cubemass, Promag 500, Promag, Promass,
Prosonic Flow, t-mass 500-digitalInstallation Instructions (EA) -
Replacing the Components for the Transmitter
Promag 400 Index C, Promag, Promass, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Replacement of parts for the sensor connection housing, remote version
Promag 400 Index C, Promag 500, Promag, Promass, Prosonic Flow, t-mass
500-digitalInstallation Instructions (EA) -
Converting the Transmitter
Promag W, L 400 Index B, Promag W, L 400 Index C
Installation Instructions (EA) -
Potting compound IP68
Promag 400 Remote Version, Promag 800 Remote Version, Promag 500, t-mass
500-digitalInstallation Instructions (EA) -
Safety Instructions for Spare Parts
Installation Instructions
Flowmeter
Installation Instructions (EA) -
Replacing the electronics
Promag 400 Index C
Installation Instructions (EA) -
Replacing connection board electronics compact and remote
Promag 400 Index C
Installation Instructions (EA) -
Activating application packages
Promag 100, 200, 400, Promass 100, 200, Prosonic Flow 100, 200, Prowirl
200, t-mass 150Installation Instructions (EA) -
Installing ground disks
Promag 10, 23, 50, 51, 53, 55, 100, 200, 300, 500, 800, 400 Index C
Installation Instructions (EA) -
Proline Promag 400
HART
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 400
PROFIBUS DP
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 400
HART
Heartbeat Verification + Monitoring application package
Special Documentation (SD) -
Promag L
Remote version IP67, type 6 enclosure –
temporary use in water
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Information on the Pressure Equipment Directive
Proline flowmeters
Special Documentation
Proline flowmeters
Special Documentation (SD) -
Proline Promag 400
Modbus RS485
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 400
EtherNet/IP
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 400
PROFIBUS DP
Acyclic data transfer
Special Documentation
Transmitter terminal assignment
Special Documentation (SD) -
Display modules A309/A310
Display with WLAN interface
Special Documentation (SD) -
Proline Promag 400
Register information Modbus RS485
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag/Promass
EtherNet/IP
System integration
Special Documentation (SD) -
Change of Directives
Special Documentation
Change of Directives
Special Documentation (SD) -
Proline Promag 400
Manufacturer information regarding firmware
updates (NE 53)
New firmware version:
Promag 400 PROFIBUS DP: 1.01.00Manufacturer Information (MI) -
Proline Promag 400
Manufacturer information regarding firmware
updates (NE 53)
New firmware version:
Promag 400 HART: 1.05.02Manufacturer Information (MI) -
Proline Promag 400
Manufacturer information regarding firmware
updates (NE 53)
New firmware version:
Promag 400 EtherNet/IP: 1.01.02Manufacturer Information (MI) -
Proline Promag 400
Manufacturer information regarding firmware updates (NE 53)
New firmware version:
Promag 400 HART: 2.00.01Manufacturer Information (MI) -
Abwassermessung, die funktioniert
Abwasser-Probeentnahme im Hofbrauhaus Freising
Case Studies (CS)08/16German -
Wastewater measurement that works
Wastewater sampling at Hofbrauhaus Freising
Case Studies (CS)08/16English -
Une mesure des eaux usées performante
Prélèvement des eaux usées chez Hofbrauhaus Freising
Case Studies (CS)08/16fr -
Industrial Ethernet for Proline flowmeters
The system integration of the future
Innovations (IN)12/17English -
Industrial Ethernet für Proline Durchflussmessgeräte
Die Systemintegration der Zukunft
Innovations (IN)12/17German -
Ethernet industriel pour débitmètres Proline
L'intégration système du futur
Innovations (IN)10/15fr -
GSD Single, GSD_DP_FL_Promag400_0x1562_0x02_0x01, 11.05.2017 (Flow, Promag 400, 0x1562)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_DP_FL_Promag400_0x1562_0x01_0x01, 27.04.2015 (Flow, Proma
g 400, 0x1562)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDS Single, EDS_EH_EIP_FL_Promag_400_0x1047_0x02_0x01, 23.10.2015 (Flow, Promag 400)
EtherNet/IP,
EtherNet IP System Version: AnyElectronic Data Sheet (EDS)2.1Language neutral -
EDS Single, EDS_EH_EIP_FL_Promag_400_0x1047_0x01_0x01, 23.10.2015 (Flow, Promag 400)
EtherNet/IP,
EtherNet IP System Version: AnyElectronic Data Sheet (EDS)1.1Language neutral -
EDD Single, PDM_HART_FL_Promag400_0x0067_0x05_0x01, 31.03.2014 (Flow, Promag 400, 0x0067)
HART,
PDM Version: 6.1, 8.1Electronic Data Description (EDD)1.00.01Language neutral -
EDD Single, AMS12_HART_FL_Promag400_0x0067_0x06_0x01, 21.08.2019 (Flow, Promag 400, 0x0067)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promag400_0x0067_0x06_0x01, 21.08.2019 (Flow, Promag 400, 0x0067)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promag400_0x1169_0x09_0x01, 05.05.2020 (Flow, Promag 400, 0x1169)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5, 14.0, 14.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promag400_0x0067_0x05_0x01, 21.08.2019 (Flow, Promag 400, 0x0067)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promag400_0x1169_0x09_0x01, 08.05.2020 (Flow, Promag 400, 0x1169)
HART,
PDM Version: 8.2.1, 9.1.0.4Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_HART_FL_Promag400_0x1169_0x08_0x01, 22.11.2018 (Flow, Promag 400, 0x1169)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promag400_0x1169_0x09_0x01, 05.05.2020 (Flow, Promag 400, 0x1169)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promag400_0x1169_0x08_0x01, 22.11.2018 (Flow, Promag 400, 0x1169)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_DP_FL_Promag400_0x1562_0x02_0x01, 11.05.2017 (Flow, Promag 400, 0x1562)
PROFIBUS DP,
PDM Version: 8.2 SP 1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_DP_FL_Promag400_0x1562_0x01_0x01, 22.02.2019 (Flow, Promag 400, 0x1562)
PROFIBUS DP,
PDM Version: 6.1, 8.1 SP1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promag400_0x0067_0x06_0x01, 16.03.2015 (Flow, Promag 400, 0x0067)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promag400_0x1169_0x09_0x01, 04.05.2020 (Flow, Promag 400, 0x1169)
HART,
Experion Version: R511
Field Device Manager Version: R511Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promag400_0x0067_0x05_0x01, 21.08.2019 (Flow, Promag 400, 0x0067)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promag400_0x0067_0x06_0x01, 16.03.2015 (Flow, Promag 400, 0x0067)
HART,
PDM Version: 6.1, 8.1 SP1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promag400_0x1169_0x08_0x01, 20.03.2017 (Flow, Promag 400, 0x1169)
HART,
PDM Version: 6.1, 8.2.1, 9.0.1Electronic Data Description (EDD)1.00Language neutral -
EDD Single, FDM_HART_FL_Promag400_0x1169_0x08_0x01, 20.03.2017 (Flow, Promag 400, 0x1169)
HART,
Field Device Manager Version: R450.1Electronic Data Description (EDD)1.00Language neutral -
DTM Single, Promag400_5x4C_HART_FW2_00_zz_Dev_Rev_8, 27.10.2020 (Flow, Promag 400, 0x1169)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 4.1 SP4Device Type Manager (DTM)1.9.0.191Language neutral -
DTM Single, Promag400_5x4C_DP_FW1_01_zz_Dev_Rev_2, 06.11.2020 (Flow, Promag 400, 0x1562)
PROFIBUS DP,
ABB 800xA Control Builder M Version: 5.1 and newer
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Freelance (Control Builder F) Version: 2013 V10.1.8311
PACTware Version: 4.1
S+ Composer Melody Version: 6.1 and newerDevice Type Manager (DTM)1.8.0.58Language neutral -
DTM Single, Promag_400_5x4C_EIP_FW_1_01_zz_Dev_Rev_2, 05.11.2020 (Flow, Promag 400, 0x1067)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.8.0.101Language neutral -
DTM Single, Promag_400_5x4C_MR4-CDIE_FW_1_00_zz_Dev_Rev_1, 06.11.2020 (Flow, Promag 400, 0x6447)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.0.59Language neutral -
DTM Single, Promag_400_5x4C_MR4_FW_1_00_zz_Dev_Rev_1, 06.11.2020 (Flow, Promag 400)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.0.59Language neutral -
DTM Single, Promag400_5x4C_HART_FW2_01_zz_Dev_Rev_9, 27.10.2020 (Flow, Promag 400, 0x1169)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 4.1 SP4Device Type Manager (DTM)1.39.0.276Language neutral -
DTM Single, Promag_400_5x4C_EIP-CDIE_FW_1_01_zz_Dev_Rev_2, 05.11.2020 (Flow, Promag 400, 0x1067)
EtherNet/IP,
DeviceCare Version: 1.04.00, 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.12.00, 2.15.00Device Type Manager (DTM)1.3.0.84Language neutral -
DTM Single, Promag_400_5x4Cxx_EIP_FW_1_00_zz_Dev_Rev_1, 05.11.2020 (Flow, Promag 400, 0x1067)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.3.0.61Language neutral -
DTM Single, Promag_400_5x4C_DP_FW_1_00_zz_Dev_Rev_1, 19.10.2020 (Flow, Promag 400, 0x1562)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.3.0.28Language neutral -
DTM Single, Promag400_5x4C_HART_FW1_05_zz_Dev_Rev_6, 27.10.2020 (Flow, Promag 400, 0x0067)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Plant Resource Manager Version: R3.11Device Type Manager (DTM)1.3.0.132Language neutral -
DTM Single, Promag_400_5x4C_MR4-CDIE_FW_2_00_zz_Dev_Rev_04, 06.11.2020 (Flow, Promag 400, 0x6469)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.10.0.148Language neutral -
DTM Single, Promag_400_5x4C_MR4_FW_2_00_zz_Dev_Rev_04, 06.11.2020 (Flow, Promag 400, 0x6469)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.10.0.148Language neutral -
DTM Single, Promag400_5x4Cxx_HART_FW1_04_zz_Dev_Rev_5, 26.10.2020 (Flow, Promag 400, 0x0067)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
FieldMate Version: 2.05
Plant Resource Manager Version: R3.10Device Type Manager (DTM)1.0.0.32Language neutral -
AOP Single, RS_EIP_FL_Promag400_5x4C_0x1067_0x01_0x01, 20.11.2018 (Flow, Promag 400, 0x1067)
EtherNet/IP,
RA RSLogix 5000 Version: V15 and laterAdd On Profile (AOP)1.65.01Language neutral -
AOP Single, RS_EIP_FL_Promag400_5x4C_0x1067_0x02_0x01, 20.11.2018 (Flow, Promag 400, 0x1067)
EtherNet/IP,
RA RSLogix 5000 Version: V15 and laterAdd On Profile (AOP)1.65.01Language neutral -
Faceplate Library, PRM_HART_Package_Flow_1_08_00, 22.07.2015 (Flow)
HART,
Plant Resource Manager Version: R3.02, R3.05, R3.10, R3.11, R3.12Faceplate1.08.00Language neutral -
Faceplate Single, PRM_HART_FL_Promag400_0x0067_0x06_0x01, 16.03.2015 (Flow, Promag 400, 0x0067)
HART,
Plant Resource Manager Version: R3.11Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_Promag400_0x0067_0x05_0x01, 31.03.2014 (Flo
w, Promag 400, 0x0067)
HART,
Plant Resource Manager Version: R3.11Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_Promag400_0x1169_0x08_0x01, 20.03.2017 (Flow, Promag 400, 0x1169)
HART,
Plant Resource Manager Version: R3.30Faceplate1.00.00Language neutral -
Note Single, Release_Notes_for_AMS_HART_Flow, 15.06.2018 (Flow)
HART,
AMS Version: AnyNote1.00.00Language neutral -
Verification DTM Library, VerificationDTM_FLOW_Modbus_RS485, 15.05.2020 (Flow)
Modbus RS485,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_PROFIBUS_DP, 15.05.2020 (Flow)
PROFIBUS DP,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_HART, 15.05.2020 (Flow)
HART,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_EIP, 15.05.2020 (Flow)
EtherNet/IP,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Promag D, Promag L, Promag W
Product Code: 5D4B-, 5D4C-, 5L4B-, 5L4C-, 5W4B-, 5W4C-
Declaration Number: EC_00276_02.16EU DeclarationGerman , English , fr -
Promass K, Promass O, Promass P, Promass Q, Promass S, Promass X, Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93, Prosonic Flow G, Prowirl D, Prowirl F, Prowirl O, Prowirl R, t-mass, t-mass A, t-mass B, T-MASS F, T-MASS I, Promass I, CNGmass, Dosimag, Dosimass, LNGmass, LPGmass, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W, Promass 40, Promass 80, Promass 83, Promass 84, Promass E, Promass F, Promass H
Product Code: 8I3B-, 8I1B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 8E5B-, 8E3B-, 8E2C-, 8E2B-, 8E1C-, 8E1B-, 8E-, 84X-, 84F-, 83X-, 83F-, 80F-, 7R2C-, 8I5B-, 8K1B-, 8O3B-, 8O5B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S1C-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 91W-, 92F-, 93C-, 93W-, 9G3B-, 9G5B-, DDA-, 7R2B-, 10D-, 10E-, 10H-, 10L-, 10P-, 10W-, 40E-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 6I5B-, 6I3B-, 6F5B-, 6F3B-, 6BAB-, 6AAB-, 65I-, 65F-, 5W8C-, 5W8B-, 5W5B-, 5W4D-, 5W4C-, 5W4B-, 5W3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRussian -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10, Dosimag
Product Code: 55S-, 5D4B-, 5D4C-, 5E1B-, 5H-, 5H1B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P3B-, 5P5B-, 5W3B-, 5W4D-, 5W5B-, 5W8B-, 5W8C-, DDA-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02228/20MiscellaneousRussian -
Promag 10, Promag 50, Promag 51, Promag 53, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 53L-, 53P-, 53W-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H1B-, 5H2B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5W4B-, 5W4C-, 5W8B-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP020 003 126MiscellaneousRussian -
Dosimag, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W3B-, 5W4B-, 5W4C-, 5W5B-, 5H2B-, 5H1B-, 5H-, 5E2B-, 5E1B-, 5D4C-, 5D4B-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRussian -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10, Dosimag, Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Promass 84, Promass 83, Promass 80, Dosimass OEM
Product Code: 5D4C-, 5P5B-, 5W5B-, 5P3B-, 5H5B-, 5W3B-, 5W4C-, 5L4C-, 53P-, 53W-, 5P1B-, 5H1B-, 5H3B-, 50W-, 50P-, 50H-, 53H-, 5E1B-, 55S-, 5P2B-, 53L-, 55H-, 5H2B-, 50L-, 53E-, 50D-, 50E-, 51W-, 5H-, 5L4B-, 5W4D-, 5W4B-, 5W8B-, 5W8C-, DDA-, 5D4B-, 10D-, 10E-, 10H-, 10P-, 10W-, 10L-, 51P-, 8E5B-, 8F1B-, 8F2B-, 8F3B-, 8H1B-, 8H3B-, 8H5B-, 8I1B-, 8I3B-, 8I5B-, 8O1B-, 8O3B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 80A-, 80E-, 80F-, 80I-, 80P-, 80S-, 83A-, 83E-, 83F-, 83H-, 83I-, 83P-, 83S-, 83X-, 84F-, 84X-, 8A1B-, 8A3B-, 8A5B-, 8BE-, 8E1B-, 8E2B-, 8E3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02246/20MiscellaneousRussian -
Promag D, Promag L, Promag W
Product Code: 5L4B-, 5D4C-, 5D4B-, O5W4C-, O5W4B-, O5L4C-, O5L4B-, O5D4C-, O5D4B-, 5W4C-, 5W4B-, 5L4C-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,D T4
Protection: NIExplosion ProtectionEnglish -
Promag D, Promag L, Promag W
Product Code: O5W4C-, O5W4B-, O5L4C-, O5L4B-, O5D4C-, O5D4B-, 5W4C-, 5W4B-, 5L4C-, 5L4B-, 5D4C-, 5D4B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,D T4
Protection: NIExplosion ProtectionEnglish -
Promag 10, Promag W, Promag 53, Promag 50, Promag 51, Promag L
Product Code: O5W1B-, 53W-, 50W-, 5W4C-, 53L-, 50L-, 5W5B-, 5W4B-, 51W-, 10W-, 10L-, 5W8B-, 5L4C-, 5L8B-
Region/Country: Great Britain
Approval Agency: WRASHygienic EquipmentEnglish -
Promag 10, Promag 50, Promag 51, Promag 53, Promag L, Promag W
Product Code: 10W-, 50L-, 50W-, 51W-, 53W-, 5L4C-, 5W4B-, 5W4C-, 5W5B-, 5W8B-, O5W1B-
Region/Country: Germany
Approval Agency: HyHygienic EquipmentGerman -
Promag 10, Promag 50, Promag 51, Promag 53, Promag L, Promag W
Product Code: O5W1B-, 5W8B-, 5W5B-, 5W4C-, 5W4B-, 5L4C-, 53W-, 51W-, 50W-, 10W-
Region/Country: USA
Approval Agency: NSFHygienic EquipmentEnglish -
Promag 10, Promag 50, Promag 51, Promag 53, Promag L, Promag W
Product Code: O5W1B-, 5W8B-, 5W5B-, 5W4C-, 5W4B-, 5L4C-, 53W-, 51W-, 50W-, 10W-
Region/Country: France
Approval Agency: ACSHygienic Equipmentfr -
Promag 10, Promag W, Promag 53, Promag 50, Promag 51, Promag L
Product Code: O5W1B-, 53W-, 50W-, 5W4C-, 53L-, 50L-, 5W5B-, 5W4B-, 51W-, 10W-, 10L-, 5W8B-, 5L4B-, 5L4C-, 5L8B-
Region/Country: Great Britain
Approval Agency: WRASHygienic EquipmentEnglish -
Promag 10, Promag 50, Promag 51, Promag 53, Promag 55, Promag L, Promag W
Product Code: 5W8C-, 5W8B-, 5W5B-, 5W4C-, 5W4B-, 5W3B-, 5L8B-, 5L4C-, 5L4B-, 55S-, 53W-, 53L-, 51W-, 50W-, 50L-, 10W-, 10L-
Region/Country: France
Approval Agency: ACSHygienic Equipmentfr -
Promag 10, Promag W, Promag 53, Promag 50, Promag 51, Promag L
Product Code: O5W1B-, 53W-, 50W-, 5W4C-, 53L-, 50L-, 5W5B-, 5W4B-, 51W-, 10W-, 10L-, 5W8B-, 5L4B-, 5L4C-, 5L8B-
Region/Country: Great Britain
Approval Agency: WRASHygienic EquipmentEnglish -
Promag W, Promag 10, Promag 50, Promag 53, Promag L
Product Code: 5W5B-, 5W4C-, 5L4C-, 53W-, 50W-, 53L-, 50L-, 10L-, 10W-, 5W4B-, 5W8B-, O5W1B-
Region/Country: Germany
Approval Agency: HyHygienic EquipmentGerman -
Promag 10, Promag 50, Promag 51, Promag 53, Promag D, Promag L, Promag P, Promag W
Product Code: 5L4B-, 5L4C-, 5L8B-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4B-, 5W4C-, 5W5B-, 5W8B-, O5P1B-, O5P2B-, O5W1B-, 10D-, 10L-, 10P-, 10W-, 50D-, 50L-, 50P-, 50W-, 51P-, 51W-, 53P-, 53W-, 5D4B-, 5D4C-
Region/Country: USA
Approval Agency: NSFHygienic EquipmentEnglish -
Promag 10, Promag 50, Promag 51, Promag 53, Promag L, Promag W
Product Code: O5W1B-, 5W8B-, 5W5B-, 5W4C-, 5W4B-, 5L4C-, 53W-, 53L-, 51W-, 50W-, 50L-, 10W-, 10L-
Region/Country: Germany
Approval Agency: HyHygienic EquipmentGerman -
Promag 10, Promag 50, Promag 51, Promag 53, Promag 55, Promag L, Promag W
Product Code: 5W8C-, 5W8B-, 5W5B-, 5W4C-, 5W4B-, 5W3B-, 5L8B-, 5L4C-, 5L4B-, 55S-, 53W-, 53L-, 51W-, 50W-, 50L-, 10W-, 10L-
Region/Country: France
Approval Agency: ACSHygienic EquipmentEnglish -
Promag 10, Promag 50, Promag 51, Promag 53, Promag L, Promag W
Product Code: O5W1B-, 5W8B-, 5W5B-, 5W4C-, 5W4B-, 5L4C-, 53W-, 51W-, 50W-, 10W-
Region/Country: Great Britain
Approval Agency: WRASHygienic EquipmentEnglish -
Promag 10, Promag 50, Promag 51, Promag 53, Promag L, Promag W
Product Code: O5W1B-, 5W8B-, 5W5B-, 5W4C-, 5W4B-, 5L4C-, 53W-, 51W-, 50W-, 50L-, 10W-
Region/Country: Germany
Approval Agency: HyHygienic EquipmentGerman -
Promag 10, Promag 50, Promag 51, Promag 53, Promag 55, Promag L, Promag P, Promag W
Product Code: 5W8C-, 5W8B-, 5W5B-, 5W4C-, 5W4B-, 5W3B-, 5L8B-, 5L4C-, 5L4B-, 55S-, 53W-, 53L-, 51W-, 50W-, 50L-, 10W-, 10L-
Region/Country: France
Approval Agency: ACSHygienic EquipmentEnglish -
Promag D, Promag W, Promag L
Product Code: 5D4C-, 5W4C-, 5L4C-
Region/Country: International
Approval Agency: ODVA
Software Version: MAJOR REV. 02, MINOR REV. 01Fieldbus ConformanceEnglish -
Promag W, Promag L, Promag D
Product Code: 5D4C-, 5W4C-, 5L4C-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: PROFIBUS PA PROFILE 3.0.2Fieldbus ConformanceEnglish -
Promag D, Promag L, Promag W
Product Code: 5D4C-, 5L4C-, 5W4C-
Region/Country: International
Approval Agency: FieldComm Group
Software Version: 02.00.01Fieldbus ConformanceEnglish -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10
Product Code: 55S-, 5D4B-, 5D4C-, 5E1B-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4B-, 5W4C-, 5W5B-, 5W8B-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Uzbekistan
Approval Agency: UZS
Approval Number: 02.6720MetrologyRussian -
Promag D, Promag P, Promag W, Promag H, Promag L, Promag E
Product Code: 5W8B-, 5W4C-, 5L4C-, 5P1B-, 5H1B-, 5H3B-, 5E1B-, 5P2B-, 5D4C-, 5H2B-, 5W4B-, 5L4B-, 5E2B-, 5D4B-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: CH.C.29.004.А NO. 59660/1MetrologyRussian -
Promag D, Promag L, Promag W
Product Code: 5D4C-, 5L4C-, 5W4C-
Region/Country: Germany
Approval Agency: TÜVRadiation ProtectionGerman , English
Accessories / Spare parts
-
-
Nr 45 Order code 71228789
Kit connection terminals, Promag 400(C)
(C) = generation index C. Consists of: Connection terminal 3-Pol stamp 1,2, Connection terminal 2-Pol stamp A,B, Connection terminal 4-Pol stamp 20-23, Connection terminal 4-Pol stamp 24-26.
-
-
-
Nr 40 Order code 71228790
Kit connec. board, D/L/W, remote,electr.
Usage: Promag 400(C) with sensor D/L/W. (C) = generation index C.
-
-
-
Nr 44 Order code 71228795
Kit connec. board, L/W, remote, sensor
Usage: Promag 400(C) with sensor L/W. (C) = generation index C.
-
-
-
Nr 30 Order code XPD0014-
Electronic Promag 400 Index C
Complete main electronic module or power supply, I/O-board and amplifier as individual boards. Complete main electronic module contains: Power supply, I/O-board, amplifier, board carrier, terminal connection, ribbon cable, installation marterial. Individual boards contains: Installation marterial, Power supply incl. terminal connection/ I/O-board incl. terminal connection/ Amplifier incl. ribbon cable.
-
-
-
Nr 39 Order code 71185788
Kit T-DAT, 100/300/400/500/500 digital
Usage: Promag/Promass 100/300/500, 500 digital, Prosonic Flow E 100, Prosonic Flow/t-mass 300, 500 digital, Promag 400(C). (C) = generation index C.
-
-
-
Nr 30 Order code XPD0040-
Electronic Promag 400 Index C update
Complete main electronic module or power supply, I/O-board with amplifier as individual boards. Complete main electronic module contains: Power supply, I/O-board, amplifier, board carrier, terminal connection, ribbon cable, installation marterial. Individual boards contains: Installation marterial, Power supply incl. terminal connection/ I/O-board incl. terminal connection and Amplifier incl. ribbon cable.
-
-
-
Nr 50 Order code XPD0017-
-
-
-
Nr 20 Order code 71443262
Kit cover, polycarbonate, 400(C), v1+v2
Usage: Promag 400 (C) (C) = generation index C. Consists of: Version 1: cover polycarbonate complete, 2x hinge pin L= 58mm plastic. Version 2: cover polycarbonate complete, O-Ring 196,44x3,53 VMQ, wire with screw lock 1,5x150.
-
Nr 20 Order code 71384170
Kit cover, alu,Promag 400(C),500 digital
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: cover Alu complete included O-Ring 196,40x3,53 HNBR, default and -50oC/-58oF, wire with screw lock 1,5x150.
-
-
-
Nr 24 Order code 71228796
Kit cover, remote, Alu
Usage: Promag 400(C) = generation index C, Promag 500, Promag/Promass/Prosonic Flow/t-mass 500 digital, sensor connection housing. Consists of: cover Alu, O-Ring 113,90x3,53 HNBR.
-
Nr 24 Order code 71228796
Kit cover, remote, Alu
Usage: Promag 400(C) = generation index C, Promag 500, Promag/Promass/Prosonic Flow/t-mass 500 digital, sensor connection housing. Consists of: cover Alu, O-Ring 113,90x3,53 HNBR.
-
Nr 24 Order code 71188176
Kit cover plastic, remote, Promag L/W
Usage: Promag 400/800, Promag 500, sensor connection housing. Consists of: cover plastic coated, O-Ring 91,67 x 3,53 FKM.
-
-
-
Nr 25 Order code 71278077
Kit 10 cover gasket, polycarbonate
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing polycarbonate. Consists of: 10x O-Ring 196,44x3,53 VMQ.
-
Nr 25 Order code 71278078
Kit cover gasket, alu,400(C),500 digital
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: 10x O-Ring 196,40x3,53 HNBR, default and -50oC/-58oF.
-
-
-
Nr 72 Order code 71188179
Kit cover gasket, plastic, Promag L/W
Usage: Promag 400/800, Promag 500, sensor connection housing. Consists of: 10x O-Ring 91,67 x 3,53 FKM.
-
-
-
Nr 71 Order code 71228793
Kit housing gasket, D/L/W,compact,400(C)
Usage: Promag 400(C) with sensor D/L/W. (C) = generation index C. Consists of: Gasket EPDM for housing/sensor D/L/W. O-Ring 29,87x1,78 HNBR for sensor- plug L/W.
-
-
-
Nr 73 Order code 71228798
Kit housing gaskets, remote, Alu
Usage: Promag 400(C) = generation index C, Promag 500, Promag 500 digital, sensor connection housing. Consists of: O-Ring 113,90x3,53 HNBR for cover, gasket EPDM for housing/sensor L/P/W, O-Ring 29,87x1,78 HNBR for sensor plug.
-
Nr 73 Order code 71228798
Kit housing gaskets, remote, Alu
Usage: Promag 400(C) = generation index C, Promag 500, Promag 500 digital, sensor connection housing. Consists of: O-Ring 113,90x3,53 HNBR for cover, gasket EPDM for housing/sensor L/P/W, O-Ring 29,87x1,78 HNBR for sensor plug.
-
-
-
Nr 12 Order code 71228794
Kit housing parts, D/L/W, compact,400(C)
Usage: Promag 400(C) with sensor D/L/W. (C) = generation index C. Consists of: 4x screw M5x18 hex cap DIN912 pla, 4x spring washer M5 DIN7980 st.pla, for housing/sensor.
-
-
-
Nr 15 Order code 71236702
Kit 10 cable glands M20x1,5, D=6-12, FPM
-
Nr 15 Order code 71236702
Kit 10 cable glands M20x1,5, D=6-12, FPM
-
-
-
Nr 17 Order code 50096840
Kit 10 cable glands M20x1,5
-
-
-
Nr 15 Order code 71236703
Kit 10 ext. M20x1,5/G1/2", FVMQ
-
Nr 15 Order code 71236703
Kit 10 ext. M20x1,5/G1/2", FVMQ
-
-
-
Nr 17 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
-
-
Nr 15 Order code 71236704
Kit 10 ext. M20x1,5/NPT1/2", FVMQ
-
Nr 15 Order code 71236704
Kit 10 ext. M20x1,5/NPT1/2", FVMQ
-
-
-
Nr 17 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
-
-
Nr 15 Order code 71236702
Kit 10 cable glands M20x1,5, D=6-12, FPM
-
Nr 15 Order code 71236705
Kit 10 cable glands M20x1,5, D=10-14,FPM
-
-
-
Nr 17 Order code 71029350
Kit 2 cable gland M20x1,5 reinf.Sensor
-
-
-
Nr 15 Order code 71236702
Kit 10 cable glands M20x1,5, D=6-12, FPM
-
Nr 15 Order code 71236702
Kit 10 cable glands M20x1,5, D=6-12, FPM
-
Nr 15 Order code 71236706
Kit plug M20x1,5/M12x1, EtherNet, FVMQ
-
Nr 15 Order code 71236706
Kit plug M20x1,5/M12x1, EtherNet, FVMQ
-
Nr 15 Order code 71236705
Kit 10 cable glands M20x1,5, D=10-14,FPM
-
Nr 15 Order code 71236706
Kit plug M20x1,5/M12x1, EtherNet, FVMQ
-
Nr 15 Order code 71236706
Kit plug M20x1,5/M12x1, EtherNet, FVMQ
-
Nr 15 Order code 71236703
Kit 10 ext. M20x1,5/G1/2", FVMQ
-
Nr 15 Order code 71236703
Kit 10 ext. M20x1,5/G1/2", FVMQ
-
Nr 15 Order code 71236706
Kit plug M20x1,5/M12x1, EtherNet, FVMQ
-
Nr 15 Order code 71236706
Kit plug M20x1,5/M12x1, EtherNet, FVMQ
-
Nr 15 Order code 71236704
Kit 10 ext. M20x1,5/NPT1/2", FVMQ
-
Nr 15 Order code 71236704
Kit 10 ext. M20x1,5/NPT1/2", FVMQ
-
Nr 15 Order code 71236706
Kit plug M20x1,5/M12x1, EtherNet, FVMQ
-
Nr 15 Order code 71236706
Kit plug M20x1,5/M12x1, EtherNet, FVMQ
-
Nr 15 Order code 71236704
Kit 10 ext. M20x1,5/NPT1/2", FVMQ
-
Nr 15 Order code 71236704
Kit 10 ext. M20x1,5/NPT1/2", FVMQ
-
-
-
Nr 13 Order code 71276494
Kit securing clamp, screw
Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Sensor housing: Promag 400(C), (C) = generation index C, Promag/Promass 500, Promag/Promass/Prosonic Flow/t-mass 500 digital. Consists of: cover clamp, screw M4x16.
-
-
-
Nr 82 Order code 71228792
Kit display protec., 400(C)/500 digital
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: display protection 1.4301, installation material.
-
-
-
Order code 5X4CXX-
Transmitter/Conversion Kit Promag 400
Same housing for compact/remote version. Corrosion-resistant transmitter version. With an integrated web server Conversion kit: For conversion of an already existing Promag to the new device generation or to another device version. Consists of all required conversion parts.
-
Order code DK5005-
-
Order code DK5CA-
Promag, cable remote version
10/50/51/53/55/400/800 1 kit includes 1 coil cable and 1 signal cable
-
Order code DK5GD-
Promag, grounding disc/protection disc
Includes 1 grounding disc/protection disc
-
Order code DK5GC-
-
Order code XPRFID-
-
-
Predecessor
-
Successor