Lean selection
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
Success stories
-
Measuring principle
Electromagnetic
-
Product headline
Flowmeter for basic process applications with easy-to-use operation concept.
Dedicated to chemical and process applications with corrosive liquids. -
Sensor features
Diverse applications – wide variety of wetted materials. Energy-saving flow measurement – no pressure loss due to cross section constriction. Maintenance-free – no moving parts.
Nominal diameter: max. DN 600 (24"). All common Ex approvals. Liner made of PTFE or PFA. -
Transmitter features
Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology.
System integration with HART, Modbus RS485. Flexible operation with app and optional display. -
Nominal diameter range
DN 15 to 600 (½ to 24")
-
Wetted materials
Liner: PFA; PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium -
Measured variables
Volume flow, conductivity, mass flow
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s) -
Measuring range
4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min)
-
Max. process pressure
PN 40, Class 300, 20K
-
Medium temperature range
Liner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F) -
Ambient temperature range
Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
DN 15 to 300 (½ to 12""): AlSi10Mg, coated
DN 350 to 600 (14 to 24""): Carbon steel with protective varnish -
Transmitter housing material
AlSi10Mg, coated
-
Degree of protection
Standard: IP66/67, Type 4X enclosure
-
Display/Operation
2.4" LCD display with touch & auto rotate; Configuration and operation via SmartBlue App (Bluetooth) possible
-
Outputs
4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA -
Digital communication
HART, MODBUS RS485
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, EAC, NEPSI, INMETRO, IND Ex, KC, JPN, UK Ex
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) -
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
Driking water approvals: ACS; NSF61, WRAS
-
-
Technical Information (TI)
Proline Promag P 10
English version - 10/2022
New version available in English
Electromagnetic flowmeter
EN 03/10/202201/07/2021Language:
English
Version:
03/10/2022
File size:
3.8 MB
File name:
TI01579DEN_0222-00.pdf
-
-
-
Operating Instruction (BA)
Proline Promag P 10
English version - 10/2022
New version available in English
Electromagnetic flowmeter HART
EN 03/10/202201/07/2021Language:
English
Version:
03/10/2022
File size:
4.5 MB
File name:
BA02069DEN_0222-00.pdf
-
-
-
Technical Information (TI)
Proline Promag P 10
-
Technical Information (TI)
English version - 10/2022Electromagnetic flowmeter
EN 03/10/202201/07/2021Language:
English
Version:
03/10/2022
File size:
3.8 MB
File name:
TI01579DEN_0222-00.pdf
-
-
-
Operating Instruction (BA)
Proline Promag P 10
-
Operating Instruction (BA)
English version - 10/2022Electromagnetic flowmeter
HARTEN 03/10/202201/07/2021Language:
English
Version:
03/10/2022
File size:
4.5 MB
File name:
BA02069DEN_0222-00.pdf
-
-
-
Operating Instruction (BA)
Proline Promag P 10
-
Operating Instruction (BA)
English version - 10/2022Electromagnetic flowmeter
Modbus RS485EN 03/10/202201/07/2021Language:
English
Version:
03/10/2022
File size:
3.9 MB
File name:
BA02072DEN_0222-00.pdf
-
-
-
Device Parameter (GP)
Proline Promag 10
-
Device Parameter (GP)
English version - 10/2022Electromagnetic flowmeter
HARTEN 03/10/202201/07/2021Language:
English
Version:
03/10/2022
File size:
1.5 MB
File name:
GP01157DEN_0222-00.pdf
-
-
-
Device Parameter (GP)
Proline Promag 10
-
Device Parameter (GP)
English version - 10/2022Electromagnetic flowmeter
Modbus RS485EN 03/10/202201/07/2021Language:
English
Version:
03/10/2022
File size:
1.6 MB
File name:
GP01158DEN_0222-00.pdf
-
-
-
Short Instruction (KA)
Flowmeter Proline 10
-
Short Instruction (KA)
English version - 10/2022HART transmitter
with electromagnetic sensorEN 03/10/202201/07/2021Language:
English
Version:
03/10/2022
File size:
3.2 MB
File name:
KA01497DEN_0322-00.pdf
-
-
-
Short Instruction (KA)
Flowmeter Proline 10
-
Short Instruction (KA)
English version - 10/2022Modbus RS485 transmitter
with electromagnetic sensorEN 03/10/202201/08/202101/07/2021Language:
English
Version:
03/10/2022
File size:
2.6 MB
File name:
KA01499DEN_0322-00.pdf
-
-
-
Short Instruction (KA)
Flowmeter Proline Promag P
-
Short Instruction (KA)
English version - 08/2022Electromagnetic sensor
EN 01/08/202201/07/202101/10/201701/02/2017Language:
English
Version:
01/08/2022
File size:
851.2 KB
File name:
KA01290DEN_0422-00.pdf
-
-
-
Installation Instructions (EA)
EA Replacing the transmitter, Ex db eb
-
Installation Instructions (EA)
English version - 12/2024Proline 10
EN 06/12/202404/04/202220/08/2021Language:
English
Version:
06/12/2024
File size:
1.3 MB
File name:
EA01371DA2_0324-00.pdf
-
-
-
Installation Instructions (EA)
EA Replacing the transmitter, non Ex/Zone 2/Div. 2/Ex db/Zone 1/Div. 1
-
Installation Instructions (EA)
English version - 12/2024Proline 10
EN 06/12/202412/06/202415/03/202303/10/202204/04/2022Language:
English
Version:
06/12/2024
File size:
1.4 MB
File name:
EA01350DA2_0624-00.pdf
-
-
Kit connec. board,floating,Promag 10/500
-
Electronic (sensor)
Drawing numberOrder code4471615502 -
-
Kit cover, glass, Polycarb., 10, Non-haz
-
Cover
Drawing numberOrder code2071505747 -
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our privacy policy .