Specs at a glance
-
Laser wavelength
532 nm
-
Hazardous area certifications
ATEX, CSA, IECEx
Field of application
The Raman Rxn-30 probe has cross-industry appeal for its robust gas-phase headspace monitoring, in situ measurements, and material compatibility. Certified for use in hazardous area environments, the Raman Rxn-30 probe can be inserted directly into processes with temperatures up to 150 degrees Celsius and pressures up to 1,000 psi. It is available with a variety of mounting options for maximum installation and sampling flexibility.
Chemical: ammonia, methanol, HyCO, reaction monitoring, blending, catalysis
Polymer: polymerization reaction monitoring
Gas-phase streams in refining: hydrogen production and recycle fuel blending, fuel characterization
Power & Energy: IGCC power plants, gas turbines
Pharmaceutical: API reaction monitoring, drying
Food & Beverage: fermentations, offgas, volatiles
Benefits
Reliable, quantitative gas-phase measurements
In situ measurement/no transfer lines or fast loops required
Can be directly inserted into processes with temperatures up to 150°C and 1,000 psi
Industry standard installation options
Direct insertion, side insertion, or sample loop
Suitable for hazardous area/classified environments
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
-
Technical Information (TI)
Rxn-30 Raman Spectroscopic Probe Technical Information
System design and specifications for the Raman Rxn-30 probe
Language:
English
Version:
01/07/2022
File size:
569.9 KB
File name:
TI01632CEN_0222.pdf
-
-
-
Operating Instruction (BA)
Rxn-30 Raman Spectroscopic Probe Operating Instructions
Commissioning, operation, and maintenance details for the Raman Rxn-30 probe
EN 28/06/2022Language:
English
Version:
28/06/2022
File size:
1.1 MB
File name:
BA02168CEN_0222.pdf
-
-
-
Short Instruction (KA)
Rxn-30 Raman Spectroscopic Probe Brief Operating Instructions
Quick start guide for the Raman Rxn-30 probe
Language:
English
Version:
01/07/2022
File size:
624.9 KB
File name:
KA01548CEN_0222.pdf
-
-
-
Ex Safety Instruction (XA)
Rxn-30 Raman Spectroscopic Probe Safety Instructions
Hazardous area certifications and installation instructions for the Raman Rxn-30 probe
EN 01/07/2022Language:
English
Version:
01/07/2022
File size:
552.1 KB
File name:
XA02748CEN_0222.pdf
-
-
-
PU (Publication)
Raman analyzer application guide for the oil & gas and chemical industries - Composition analysis of gas streams and LNG
A guide to our Raman spectroscopy analyzer and probe portfolio, powered by Kaiser Raman technology, for composition analysis of gas streams and LNG (includes the Raman Rxn4 analyzer, the Raman Rxn5 analyzer, the Raman Rxn-30 probe, and Raman Rxn-41 probe) in the chemical industry and oil & gas industry.
Language:
English
Version:
08/12/2021
File size:
2.6 MB
File name:
PU01445CEN_0121.pdf
-
-
-
PU (Publication)
Raman Rxn-30 probe - Gas phase analysis
An overview brochure about the Raman Rxn-30 probe, a Raman spectroscopy probe for gas phase measurement powered by Kaiser Raman technology in the Oil & Gas industry and Chemical industry.
Language:
English
Version:
20/01/2022
File size:
489.6 KB
File name:
PU01452CEN_0122.pdf
-
-
-
PU (Publication)
Industry standards on gas quality - Raman Rxn5 analyzer (syngas/LNG) andRaman Rxn4 analyzer (LNG)
A list of industry gas quality standards that our Raman Rxn5 analyzer meets for syngas / LNG and our Raman Rxn4 analyzer meets for LNG.
Language:
English
Version:
20/04/2022
File size:
432.5 KB
File name:
PU01463CEN_0122.pdf
-
-
-
PU (Publication)
Raman Rxn5 analyzer - Laser-based composition analysis
An overview brochure about our Raman Rxn5 analyzer (including the Raman Rxn-30 probe, the Rxn-40 probe, and the Rxn-41 probe), a Raman spectroscopy analyzer system for gas phase measurements powered by Kaiser Raman technology.
Language:
English
Version:
28/10/2021
File size:
503.5 KB
File name:
PU01444CEN_0121.pdf
-
-
-
Innovation (IN)
Raman spectrographic probes - Robust optical measurement of chemical composition
An overview brochure about our Raman spectroscopy probe portfolio including the Rxn-10 probe, Rxn-20 probe, Rxn-30 probe, Rxn-40 probe, Rxn-41 probe, Rxn-45 probe, Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single use optic system / SUB, immersion optic , non-contact optic), powered by Kaiser Raman technology.
Language:
English
Version:
26/10/2021
File size:
4.9 MB
File name:
IN01225CEN_0121.pdf
-
-
-
Innovation (IN)
Raman technology for the chemical industry - Reliable composition measurement of chemical process streams
An overview brochure about our Raman spectroscopy analyzer systems, powered by Kaiser Raman technology, for the chemical industry (includes the Raman Rxn2 analyzer, Raman Rxn4 analyzer, Raman Rxn5 analyzer, and the Raman Rxn-10 probe, Raman Rxn-20 probe, Raman Rxn-30 probe, Raman Rxn-40 probe, and Raman Rxn-41 probe).
EN 18/10/2021Language:
English
Version:
18/10/2021
File size:
10.6 MB
File name:
IN01223CEN_0121.pdf
-
-
-
White paper
Getting a hydrogen signal in natural gas
This whitepaper discusses the role of Raman spectroscopy (using a Raman Rxn5 analyzer and Rxn-30 probe) to safely control the injection of H₂ (hydrogen blending) in natural gas which is an important focus in energy transition.
Language:
English
Version:
13/09/2022
File size:
1.6 MB
File name:
WP01184CEN_0122.pdf
-
-
-
AI (Application note)
Raman spectroscopy to support REACH registration of gases
This note examines Raman spectroscopy as a useful tool to support REACH registration of gases.
Language:
English
Version:
21/08/2021
File size:
218.4 KB
File name:
AI01203CEN_0121.pdf
-
-
-
AI (Application note)
Captive hydrogen: production analytics overview
This application note studies the use of a Raman Rxn5 analyzer for the reliable measurement of captive hydrogen gas streams.
Language:
English
Version:
15/10/2021
File size:
256.3 KB
File name:
AI01263CEN_0121.pdf
-
-
-
AI (Application note)
Captive hydrogen: natural gas feed to primary reformer
This application note studies the use of a Raman Rxn5 analyzer for the measurement of natural gas feed streamsto the reformer.
Language:
English
Version:
15/10/2021
File size:
610.6 KB
File name:
AI01264CEN_0121.pdf
-
-
-
AI (Application note)
Captive hydrogen: fuel gas to reformer furnaces
This application note examines the use of a Raman Rxn5 analyzer for the measurement of fuel gas streams to reformer furnaces.
Language:
English
Version:
15/10/2021
File size:
594.9 KB
File name:
AI01265CEN_0121.pdf
-
-
-
AI (Application note)
Captive hydrogen: high temperature shift converter outlet
This application note examines the use of a Raman Rxn5 analyzer for the measurement of high temperature shift syngas converter stream.
Language:
English
Version:
15/10/2021
File size:
618.6 KB
File name:
AI01268CEN_0121.pdf
-
-
-
AI (Application note)
Captive hydrogen: CO2 absorber outlet - feed to PSA
This application noteexamines the use of a Raman Rxn5 analyzer for the measurement of CO2 absorber outlet stream to PSA.
Language:
English
Version:
15/10/2021
File size:
567.3 KB
File name:
AI01270CEN_0121.pdf
-
-
-
AI (Application note)
Merchant hydrogen: low temperature shift converter outlet
This application note merchant hydrogen examines the use of a Raman Rxn5 analyzer for the measurement of merchant hydrogen low temperature shiftsyngas converter streams.
Language:
English
Version:
02/11/2021
File size:
591.1 KB
File name:
AI01299CEN_0121.pdf
-
-
-
AI (Application note)
Merchant hydrogen: PSA unit H2 stream
This application note examines theuse of a Raman Rxn5 analyzer to measure the PSA outlet to H2 stream in merchant hydrogen production.
Language:
English
Version:
02/11/2021
File size:
659.7 KB
File name:
AI01301CEN_0121.pdf
-
-
-
AI (Application note)
Merchant hydrogen: raw syngas – primary reformer outlet
This applicationnote examines the use of a Raman Rxn5 analyzer for the measurement of merchant hydrogen primary reformer syngas streams.
Language:
English
Version:
30/11/2021
File size:
551.6 KB
File name:
AI01344CEN_0121.pdf
-