Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.
Product picture Raman Rxn-30 probe side view aiming right and down

Raman Rxn-30 probe

Providing reliable, quantitative gas-phase measurements in a process environment

KR30
Please Wait (spinning wheel)
Loading price
Prices temporarily unavailable
Price on request
from CHF ??.-
Filter
Filter downloads

Back

Configure to download the CAD drawings of this product

71 documents
    • Technical Information (TI)

    Rxn-30 Raman Spectroscopic Probe Technical Information

    • Technical Information (TI)
    English version - 07/2022
    New version available in English

    System design and specifications for the Raman Rxn-30 probe

    • Operating Instruction (BA)

    Rxn-30 Raman Spectroscopic Probe Operating Instructions

    • Operating Instruction (BA)
    English version - 06/2022
    New version available in English

    Commissioning, operation, and maintenance details for the Raman Rxn-30 probe

    • Short Instruction (KA)

    Rxn-30 Raman Spectroscopic Probe Brief Operating Instructions

    • Short Instruction (KA)
    English version - 07/2022
    New version available in English

    Quick start guide for the Raman Rxn-30 probe

    • Ex Safety Instruction (XA)

    Rxn-30 Raman Spectroscopic Probe Safety Instructions

    • Ex Safety Instruction (XA)
    English version - 07/2022
    New version available in English

    Hazardous area certifications and installation instructions for the Raman Rxn-30 probe

    • PU (Publication)

    Raman analyzer application guide for the oil & gas and chemical industries - Composition analysis of gas streams and LNG

    • PU (Publication)
    English version - 12/2021
    New version available in English

    A guide to our Raman spectroscopy analyzer and probe portfolio, powered by Kaiser Raman technology, for composition analysis of gas streams and LNG (includes the Raman Rxn4 analyzer, the Raman Rxn5 analyzer, the Raman Rxn-30 probe, and Raman Rxn-41 probe) in the chemical industry and oil & gas industry.

    • PU (Publication)

    Raman Rxn-30 probe - Gas phase analysis

    • PU (Publication)
    English version - 01/2022
    New version available in English

    An overview brochure about the Raman Rxn-30 probe, a Raman spectroscopy probe for gas phase measurement powered by Kaiser Raman technology in the Oil & Gas industry and Chemical industry.

    • PU (Publication)

    Industry standards on gas quality - Raman Rxn5 analyzer (syngas/LNG) andRaman Rxn4 analyzer (LNG)

    • PU (Publication)
    English version - 04/2022
    New version available in English

    A list of industry gas quality standards that our Raman Rxn5 analyzer meets for syngas / LNG and our Raman Rxn4 analyzer meets for LNG.

    • PU (Publication)

    Raman Rxn5 analyzer - Laser-based composition analysis

    • PU (Publication)
    English version - 10/2021
    New version available in English

    An overview brochure about our Raman Rxn5 analyzer (including the Raman Rxn-30 probe, the Rxn-40 probe, and the Rxn-41 probe), a Raman spectroscopy analyzer system for gas phase measurements powered by Kaiser Raman technology.

    • Innovation (IN)

    Raman spectrographic probes - Robust optical measurement of chemical composition

    • Innovation (IN)
    English version - 10/2021
    New version available in English

    An overview brochure about our Raman spectroscopy probe portfolio including the Rxn-10 probe, Rxn-20 probe, Rxn-30 probe, Rxn-40 probe, Rxn-41 probe, Rxn-45 probe, Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single use optic system / SUB, immersion optic , non-contact optic), powered by Kaiser Raman technology.

    • Innovation (IN)

    Raman technology for the chemical industry - Reliable composition measurement of chemical process streams

    • Innovation (IN)
    English version - 10/2021
    New version available in English

    An overview brochure about our Raman spectroscopy analyzer systems, powered by Kaiser Raman technology, for the chemical industry (includes the Raman Rxn2 analyzer, Raman Rxn4 analyzer, Raman Rxn5 analyzer, and the Raman Rxn-10 probe, Raman Rxn-20 probe, Raman Rxn-30 probe, Raman Rxn-40 probe, and Raman Rxn-41 probe).

    • White paper

    Getting a hydrogen signal in natural gas

    • White paper
    English version - 09/2022
    New version available in English

    This whitepaper discusses the role of Raman spectroscopy (using a Raman Rxn5 analyzer and Rxn-30 probe) to safely control the injection of H₂ (hydrogen blending) in natural gas which is an important focus in energy transition.

    • AI (Application note)

    Raman spectroscopy to support REACH registration of gases

    • AI (Application note)
    English version - 08/2021
    New version available in English

    This note examines Raman spectroscopy as a useful tool to support REACH registration of gases.

    • AI (Application note)

    Captive hydrogen: production analytics overview

    • AI (Application note)
    English version - 10/2021
    New version available in English

    This application note studies the use of a Raman Rxn5 analyzer for the reliable measurement of captive hydrogen gas streams.

    • AI (Application note)

    Captive hydrogen: natural gas feed to primary reformer

    • AI (Application note)
    English version - 10/2021
    New version available in English

    This application note studies the use of a Raman Rxn5 analyzer for the measurement of natural gas feed streamsto the reformer.

    • AI (Application note)

    Captive hydrogen: fuel gas to reformer furnaces

    • AI (Application note)
    English version - 10/2021
    New version available in English

    This application note examines the use of a Raman Rxn5 analyzer for the measurement of fuel gas streams to reformer furnaces.

    • AI (Application note)

    Captive hydrogen: high temperature shift converter outlet

    • AI (Application note)
    English version - 10/2021
    New version available in English

    This application note examines the use of a Raman Rxn5 analyzer for the measurement of high temperature shift syngas converter stream.

    • AI (Application note)

    Captive hydrogen: CO2 absorber outlet - feed to PSA

    • AI (Application note)
    English version - 10/2021
    New version available in English

    This application noteexamines the use of a Raman Rxn5 analyzer for the measurement of CO2 absorber outlet stream to PSA.

    • AI (Application note)

    Merchant hydrogen: low temperature shift converter outlet

    • AI (Application note)
    English version - 11/2021
    New version available in English

    This application note merchant hydrogen examines the use of a Raman Rxn5 analyzer for the measurement of merchant hydrogen low temperature shiftsyngas converter streams.

    • AI (Application note)

    Merchant hydrogen: PSA unit H2 stream

    • AI (Application note)
    English version - 11/2021
    New version available in English

    This application note examines theuse of a Raman Rxn5 analyzer to measure the PSA outlet to H2 stream in merchant hydrogen production.

    • AI (Application note)

    Merchant hydrogen: raw syngas – primary reformer outlet

    • AI (Application note)
    English version - 11/2021
    New version available in English

    This applicationnote examines the use of a Raman Rxn5 analyzer for the measurement of merchant hydrogen primary reformer syngas streams.