Specs at a glance
Hazardous area certifications
Field of application
The Raman Rxn-30 probe has cross-industry appeal for its robust gas-phase headspace monitoring, in situ measurements, and material compatibility. Certified for use in hazardous area environments, the Raman Rxn-30 probe can be inserted directly into processes with temperatures up to 150 degrees Celsius and pressures up to 68.9 barg (1,000 psig). It is available with a variety of mounting options for maximum installation and sampling flexibility.
Chemical: ammonia, methanol, HyCO, reaction monitoring, blending, catalysis
Benefits
Reliable, quantitative gas-phase measurements
In situ measurement/no transfer lines or fast loops required
Can be directly inserted into processes with temperatures up to 150 °C and 68.9 barg (1,000 psig)
Industry standard installation options
Direct insertion, side insertion, or sample loop
Suitable for hazardous area/classified environments
Extended selection
High-end products
Highly functional and convenient
Technical excellence
Simplicity
©Endress+Hauser
Simple products
Easy to select, install and operate
Technical excellence
Simplicity
Standard products
Reliable, robust and low-maintenance
Technical excellence
Simplicity
High-end products
Highly functional and convenient
Technical excellence
Simplicity
Specialized products
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections
Technical excellence
Simplicity
Fundamental selection
Meet your basic measurement needs
Technical excellence
Simplicity
Lean selection
Handle your core processes easily
Technical excellence
Simplicity
Extended selection
Optimize your processes with innovative technologies
Technical excellence
Simplicity
Xpert selection
Master your most challenging applications
Technical excellence
Simplicity
Loading alternative products
Success stories
LNG: truck loading
Find out how to accurately measure the composition of LNG at truck loading with the use of a Raman Rxn4 analyzer.
Read the full story
Raman method for custody transfer measurements of LNG
Check out the findings from the GERG report on the use of a Raman Rxn4 analyzer and Raman Rxn-41 cryogenic probe for the reliable chemical composition measurement in LNG custody transfer applications.
Read the full story
Spectral coverage
Probe spectral coverage is limited by the coverage of the analyzer being used.
Temperature
Temperature, Rxn-30 probe: -20 to 150 °C / -4 to 302 °F
Maximum laser power into probehead (mW)
Sample interface
Operating temperature, probehead: -20 to 150 °C / -4 to 302 °F Temperature ramp: ≤ 6 °C/min ≤ 10.8 °F/min
Pressure
Max pressure: (at sample) 68.9 barg / 1000 psig
Wetted materials
316/316L stainless steel PTFE Sapphire Fused silica glass
Gas stream filtration
20 μm or better Integrated 20 μm particle filter standard with Rxn-30 probes
Hazardous area certifications
Most downloaded
Rxn-30 Raman Spectroscopic Probe
Technical Information
English version - 07/2022
System design and specifications for the Raman Rxn-30 probe
Language:
English
Version:
01/07/2022
File size:
569.9 KB
File name:
TI01632CEN_0222.pdf
88 documents
Rxn-30 Raman Spectroscopic Probe
Technical Information
System design and specifications for the Raman Rxn-30 probe
Language:
English
Version:
01/07/2022
File size:
569.9 KB
File name:
TI01632CEN_0222.pdf
Rxn-30 Raman Spectroscopic Probe
Operating Instructions
Commissioning, operation, and maintenance details for the Raman Rxn-30 probe
Language:
English
Version:
28/06/2022
File size:
1.1 MB
File name:
BA02168CEN_0222.pdf
Rxn-30 Raman Spectroscopic Probe
Brief Operating Instructions
Quick start guide for the Raman Rxn-30 probe
Language:
English
Version:
01/07/2022
File size:
624.9 KB
File name:
KA01548CEN_0222.pdf
Rxn-30 Raman Spectroscopic Probe Safety Instructions
Hazardous area certifications and installation instructions for the Raman Rxn-30 probe
EN
Spanish French Italian Japanese Korean Portuguese Russian Chinese
08/08/2023
Language:
English
Version:
08/08/2023
File size:
1.8 MB
File name:
XA02748CEN_0323.pdf
Raman Rxn5 analyzer - Laser-based composition analysis
An overview brochure about our Raman Rxn5 analyzer (including the Raman Rxn-30 probe, the Rxn-40 probe, and the Rxn-41 probe), a Raman spectroscopy analyzer system for gas phase measurements powered by Kaiser Raman technology.
Language:
English
Version:
28/10/2021
File size:
499.9 KB
File name:
PU01444CEN_0121.pdf
Raman analyzer application guide for the oil & gas and chemical
industries - Composition analysis of gas streams and LNG
A guide to our Raman spectroscopy analyzer and probe portfolio, powered by Kaiser Raman technology, for composition analysis of gas streams and LNG (includes the Raman Rxn4 analyzer, the Raman Rxn5 analyzer, the Raman Rxn-30 probe, and Raman Rxn-41 probe) in the chemical industry and oil & gas industry.
Language:
English
Version:
08/12/2021
File size:
2.5 MB
File name:
PU01445CEN_0121.pdf
Industry standards on gas quality - Raman Rxn5
analyzer (syngas/LNG) andRaman Rxn4 analyzer (LNG)
A list of industry gas quality standards that our Raman Rxn5 analyzer meets for syngas / LNG and our Raman Rxn4 analyzer meets for LNG.
Language:
English
Version:
20/04/2022
File size:
432.5 KB
File name:
PU01463CEN_0122.pdf
Raman Rxn-30 probe - Gas phase analysis
An overview brochure about the Raman Rxn-30 probe, a Raman spectroscopy probe for gas phase measurement powered by Kaiser Raman technology in the Oil & Gas industry and Chemical industry.
Language:
English
Version:
20/01/2022
File size:
489.6 KB
File name:
PU01452CEN_0122.pdf
Raman technology for the chemical industry - Reliable
composition measurement of chemical process streams
An overview brochure about our Raman spectroscopy analyzer systems, powered by Kaiser Raman technology, for the chemical industry (includes the Raman Rxn2 analyzer, Raman Rxn4 analyzer, Raman Rxn5 analyzer, and the Raman Rxn-10 probe, Raman Rxn-20 probe, Raman Rxn-30 probe, Raman Rxn-40 probe, and Raman Rxn-41 probe).
Language:
English
Version:
18/10/2021
File size:
10.6 MB
File name:
IN01223CEN_0121.pdf
Raman spectrographic probes - Robust optical measurement
of chemical composition
An overview brochure about our Raman spectroscopy probe portfolio including the Rxn-10 probe, Rxn-20 probe, Rxn-30 probe, Rxn-40 probe, Rxn-41 probe, Rxn-45 probe, Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single use optic system / SUB, immersion optic , non-contact optic), powered by Kaiser Raman technology.
Language:
English
Version:
26/10/2021
File size:
4.9 MB
File name:
IN01225CEN_0121.pdf
Mesure optique robuste de la composition chimique
-
Language:
French
Version:
16/03/2023
File size:
776 KB
File name:
IN01225CFR.pdf
Language:
Japanese
Version:
01/03/2023
File size:
16.5 MB
File name:
IN01223CJA_0121.pdf
Getting a hydrogen signal in natural gas
This whitepaper discusses the role of Raman spectroscopy (using a Raman Rxn5 analyzer and Rxn-30 probe) to safely control the injection of H₂ (hydrogen blending) in natural gas which is an important focus in energy transition.
Language:
English
Version:
13/09/2022
File size:
1.6 MB
File name:
WP01184CEN_0122.pdf
Tandem Raman and IR spectroscopies for monitoring of soil gases in
CO2 sequestration
This work describes Raman and IR spectroscopies as a viable means of comparing CO2 concentrations.
Language:
English
Version:
21/08/2021
File size:
303.3 KB
File name:
AI01204CEN_0121.pdf
Captive hydrogen: fuel gas to reformer furnaces
This application note examines the use of a Raman Rxn5 analyzer for the measurement of fuel gas streams to reformer furnaces.
Language:
English
Version:
15/10/2021
File size:
594.9 KB
File name:
AI01265CEN_0121.pdf
Captive hydrogen: CO2 absorber outlet - feed to PSA
This application note examines the use of a Raman Rxn5 analyzer for the measurement of CO2 absorber outlet stream to PSA.
Language:
English
Version:
15/10/2021
File size:
567.3 KB
File name:
AI01270CEN_0121.pdf
Captive hydrogen: PSA unit H2 stream
This application note examines the use of a Raman Rxn5 analyzer for the measurement of the PSA outlet to H2 stream.
Language:
English
Version:
15/10/2021
File size:
669.2 KB
File name:
AI01271CEN_0121.pdf
Captive hydrogen: CO2 absorber recovery system
This application note discusses the use of the Raman Rxn5 analyzer to measure CO2 absorber recovery streams in captivehydrogen production.
Language:
English
Version:
15/10/2021
File size:
424.9 KB
File name:
AI01272CEN_0121.pdf
Merchant hydrogen: HyCO production analytics overview
This application note studies the use of a Raman Rxn5 analyzer for the reliable measurement of merchant hydrogen gas streams.
Language:
English
Version:
02/11/2021
File size:
253.7 KB
File name:
AI01294CEN_0121.pdf
Merchant hydrogen: natural gas feed to primary reformer
This application note studies the use of a Raman Rxn5 analyzer for the reliable measurement of natural gas feed to the primary reformer.
Language:
English
Version:
02/11/2021
File size:
614.6 KB
File name:
AI01295CEN_01.21.pdf
Merchant hydrogen: raw syngas – primary reformer outlet
This application note examines the use of a Raman Rxn5 analyzer for the measurement of merchant hydrogen primary reformer syngas streams.
Language:
English
Version:
02/11/2021
File size:
595.4 KB
File name:
AI01296CEN_0121.pdf
Merchant hydrogen: raw syngas - secondary reformer outlet
This application note examines the use of a Raman Rxn5 analyzer for the measurement of merchant hydrogen secondary reformer syngas streams.
Language:
English
Version:
02/11/2021
File size:
589.4 KB
File name:
AI01297CEN_0121.pdf
Merchant hydrogen: low temperature shift converter outlet
This application note merchant hydrogen examines the use of a Raman Rxn5 analyzer for the measurement of merchant hydrogen low temperature shift syngas converter streams.
Language:
English
Version:
02/11/2021
File size:
591.1 KB
File name:
AI01299CEN_0121.pdf
Merchant hydrogen: CO2 absorber outlet – feed to PSA
This application note examines the use of a Raman Rxn5 analyzer to measure the CO2 absorber outlet stream to PSAin merchant hydrogen production.
Language:
English
Version:
02/11/2021
File size:
557.9 KB
File name:
AI01300CEN_0121.pdf
Merchant hydrogen: CO2 absorber recovery stream
This application note discusses the use of the Raman Rxn5 analyzer to measure CO2 absorber recovery streams in merchant hydrogen production.
Language:
English
Version:
02/11/2021
File size:
431.6 KB
File name:
AI01302CEN_0121.pdf
Ammonia: CO2 absorber outlet - methanator inlet
This application note examines the use of a Raman Rxn5 analyzer for the measurement of the CO2 absorber outlet-methanator inlet in ammonia production.
Language:
English
Version:
03/11/2021
File size:
566.2 KB
File name:
AI01317CEN_0121.pdf
Ammonia: converter exit stream
This application note examines the use of a Raman Rxn5 analyzer for the measurement of the converter exit gas feed stream in ammonia production.
Language:
English
Version:
03/11/2021
File size:
459.1 KB
File name:
AI01320CEN_0121.pdf
Ammonia: synthesis loop purge gas
This application note examines the use of a Raman Rxn5 analyzer for the measurement of the synthesis loop purge gas stream in ammonia production.
Language:
English
Version:
03/11/2021
File size:
432.3 KB
File name:
AI01321CEN_0121.pdf
Ammonia: natural gas feed to primary reformer
This application note studies the use of the Raman Rxn5 analyzer to measure the natural gas feed stream to the reformer in ammonia production.
Language:
English
Version:
03/11/2021
File size:
610.7 KB
File name:
AI01311CEN_0121.pdf
Ammonia: fuel gas to reformer furnaces
This application note studies the use of the Raman Rxn5 analyzer to measure the fuel gas stream to primary reformer furnace in ammonia production.
Language:
English
Version:
03/11/2021
File size:
586 KB
File name:
AI01312CEN_0121.pdf
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our privacy policy .
Customize
Accept only essential
Accept all