Easytemp TSM487
Modular RTD thermometer
Comprehensive and common temperature measurement technology for almost all branches of industry
The thermometer is mainly used in the chemical industry but also finds its use in other branches. Preferred applications are vessels or pipes where no high process pressures and no extreme temperatures appear. The device with head transmitter is a complete unit ready for use with enhanced measurement accuracy and reliability compared to directly wired sensors. A variety of dimensions offers flexible application possibilities.
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Accuracy
class A acc. to IEC 60751
-
Response time
t50 = 4 s
t90 = 8 s -
Max. process pressure (static)
at 20 °C: 20 bar (290 psi)
-
Operating temperature range
PT 100:
-30 °C ...200 °C
(-22 °F ...392 °F) -
Max. immersion length on request
up to 250,00 mm (9,84'')
-
Quick selection
Individual configuration
-
Benefits
High degree of flexibility thanks to modular design with standard terminal heads as per DIN EN 50446 and customer-specific immersion lengths
High degree of insert compatibility and design as per DIN 43772
-
Field of application
The TSM487 compact thermometer is used for universal applications. Preferred applications are in vessels or in pipes, where no high process pressures and no extreme temperatures appear. The TSM487 includes a fiberglass insulated insert which is...
Documents / Manuals / Software
-
Technical Information
Easytemp® TSM487
Compact thermometer with screw-in thread for universal applications
Technical Information (TI) -
Brief Operating Instructions
TMT187, TMT188
TSM187, TSM487
Temperaturkopftransmitter iTEMP® Pt100 TMT187, TC TMT188;
Kompaktthermometer Easytemp TSM187, TSM487Short Instruction (KA)04/13German , English , fr -
Измерение температуры
Ключевые особенности термометров Endress+Hauser для нефтегазовой отрасли
Competence Brochure (CP)08/11Russian -
Инженерные решения по термометрии
Специальные решения по термометрии для химической и
нефтеперерабатывающей промышленностиCompetence Brochure (CP)04/10Russian -
Catálogo soluciones esenciales
Alta calidad a precios competitivos
Competence Brochure (CP)01/17Spanish -
E-direct Produktcatalogus 2018-2019
High quality, low price
Endress+Hauser Catalogues (EC)10/18Dutch -
Catalogue Produits E-direct 2019/2020 Français
La qualité Endress+Hauser à petit prix !
Endress+Hauser Catalogues (EC)09/19fr -
E-direct Produktkatalog 2019/2020
Hohe Qualität zum kleinen Preis!
Endress+Hauser Catalogues (EC)06/20German -
RTD-thermometer
Product Code: TSM487-
Declaration Number: HE_00525_01.17
Manufacturer Specification: RoHSManufacturer DeclarationEnglish -
RTD-thermometer, Process TC Heavy duty, Process TC General purpose, Process TC Explosion proof, Process TC direct in contact, Process TC Direct contact, Process RTD Hygienic, Process RTD Heavy duty, Process RTD General purpose, Process RTD Explosion proof, Process RTD direct in contact, Process RTD Direct contact, Plugs RTD direct contact, Magphant, Low cost RTD General purpose, Industrial Modular Thermometer
Product Code: TR15-, TR13-, TR12-, TR11-, TR10-, TMT470L-, TMT162R-, TMT162C-, TMT142R-, TMT142C-, TMR35L-, TMR35-, TMR31L-, TMR31-, TM411-, TM401-, TH56-, TH55-, TH54-, TH53-, TH52-, TH51-, TR24-, TTR35-, TTR31-, TST90-, TST602-, TST487-, TST434-, TST41N-, TST414-, TST410-, TST40N-, TST310-, TST187-, TSM487-, TSM187-, TSC310-, TR88-, TR66-, TR65-, TR63-, TR62-, TR61-, TR25-, TH27-, T55-, T54-, T53-, T15-, T14-, T13-, OTR96-, OTR95-, OTR94-, OTR93-, OTR92-, OTR91-, OTR90-, OTR35-, OTR31-, MLTTS01-, MLTTS00-, GPTL-, DTT35L-, DTT35-, DTT31L-, DTT31-, TAF11-, TH18-, TH17-, TH15-, TH14-, TH13-, TH12-, TH11-, TEC420-, TC88-, TC66-, TC65-, TC63-, TC62-, TC61-, TC15-, TC13-, TC12-, TC10-, TAF16-, TAF12T-, TAF12S-, TAF12D-
Declaration Number: EC_00568_01.17EU DeclarationGerman , English , fr -
RTD-thermometer
Product Code: TSM187-, TSM487-
Declaration Number: EC_00340_01.16EU DeclarationGerman , English , fr -
ACCESSORIES: RTD INSERT, ACCESSORIES: TC INSERT, ACCESSORIES: T_INSERTS, Low cost RTD General purpose, Process RTD Direct contact, Process RTD General purpose, Process RTD Heavy duty, RTD-thermometer
Product Code: TR88-, TS111-, TSM187-, TSM487-, TST187-, TST310-, TST40N-, TST410-, TST414-, TST41N-, TST434-, TST487-, TST602-, TR66-, TR65-, TR63-, TR62-, TR61-, TR25-, TR24-, TR15-, TR13-, TR12-, TR11-, TR10-, TPR300-, TPR100-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: IT.C.32.004.A_66572MetrologyRussian
Accessories / Spare parts
-
-
Order code 51001112
-
Order code TMT187-
iTEMP TMT187, Head Transmitter RTD
Temperature transmitter Application: RTD. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.
-
-
Successor