Enter at least 2 characters to start the search.

TMT142C
TC Thermometer, fieldtransmitter, display

TC thermometer TMT142C with field transmitter ©Endress+Hauser

Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry

The robust thermometer is designed for use in demanding and safety relevant applications e.g. in the Chemical, Oil & Gas and Energy industry. The thermometer fulfills the corresponding safety requirements due to various certificates and tests. The use of a transmitter leads to higher accuracy and reliability in comparison to directly wired sensors.

Quick selection

Choose from our suggested options
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

or

Individual configuration

Continue your selection from all possible options
  • Benefits

    • Dual compartment housing

    • Backlit display with large measured value, bar graph and fault condition indication

    • Galvanic isolation 2 kV (sensor input to the output)

    • Wide range of threaded thermowell connections available as standard

    • Replaceable measuring...

  • Field of application

    The temperature assembly TMT142C is a compact thermometer specifically designed to fulfill the requirements of different process industries such as the chemical, petrochemical and energy but even suitable to other general purpose applications.
    The...

Features and specifications

Back

Details

  • Measuring principle

    Thermocouple

  • Characteristic / Application

    US style

    modular temperature assembly

    for heavy duty applications

    suitable for hazardous areas

    threaded process connection

    to use with thermowell

    backlit display

  • Thermowell / protection tube

    to use with thermowell

  • Insert / probe

    mineral insulated (MI), flexible

  • Outer diameter protection tube / Insert

    Not defined

  • Max. immersion length on request

    up to 30.000,00 mm (1.181,10'')

  • Material protection tube/ thermowell

    Not defined

  • Optional coating

    Not defined

  • Process connection

    male thread:

    G1/2"

    NPT1/2"

    NPT3/4"

    union nut:

    NPT1/2"

    M24x1.5

  • Tip shape

    straight

  • Operating temperature range

    Type K:

    -40 °C ...800 °C

    (-40 °F ...1.472 °F)

    Type J:

    -40 °C ... 750 °C

    (-40 °F ...1.382 °F)

  • Max. process pressure (static)

    depending on thermowell

  • Accuracy

    class 1 acc. to IEC 60584

    class 2 acc. to IEC 60584

  • Response time

    depending on configuration

    t50 = 3 s

    t90 = 7 s

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    ATEX II

    Explosion proof

Documents / Manuals / Software

Accessories / Spare parts

Nr
Order code
Specification