Deltapilot S DB51
Ce produit n'est plus disponible.
Veuillez vérifier la disponibilité de la nouvelle génération dans la section Prédécesseur / Successeur ou contactez votre agence Endress+Hauser locale.
Documents / Manuels / Logiciels
-
Deltapilot S Pressure sensor with CONTITE measuring
Deltapilot S DB50(A), DB50L, DB50S, DB51(A), DB52(A), DB53(A), Pressure
sensor with CONTITE measuring cellInformation technique (TI) -
Information techniquedeltapilot S DB 50, DB 51, DB 52, DB 50 L, DB 53
Mesure de niveau hydrostatique
Sondes de pression avec cellule de mesure CONTITE étanche, protégée,
stable à long terme.
Pour
produits alimentaires, eau, eaux usées, produits chimiques et
pharmaceutiques.Information technique (TI) -
Weld-in adapter, process adapter and flanges
Level and pressure measurement
Information technique (TI) -
Operating Instructions Electronic insert FEB 20 with INTENSOR Protocol /
FEB 22 with HART Protocol
Pressure sensors with CONTITE measuring cell watertight,
condensation-free, stable.
For foodstuffs, water, wastewater, chemicals
and pharmaceutical.Mise en service (BA) -
Operating Instructions Deltapilot S PROFIBUS-PA Hydrostatic Level
Measurement
Pressure sensors with CONTITE measuring cell watertight,
condensation-free, stable.
For foodstuffs, water, wastewater, chemicals
and pharmaceutical.Mise en service (BA) -
Operating Instructions Deltapilot S Foundation Fieldbus Hydrostatic
Level Measurement
Pressure sensors with CONTITE measuring cell watertight,
condensation-free, stable.
For foostuffs, water, wastewater, chemicals and
pharmaceuticals.Mise en service (BA) -
Mise en serviceElectronique FEB 20
avec protocole INTENSOR FEB 22 avec protocole HART
Mise en service (BA) -
Operating Instructions Deltapilot S FEB 11/ FEB 17; FEB 11 P/ FEB 17 P.
Electronic insert.
Instructions condensées (KA)08/96Allemand , Anglais , Espagnol , fr , Italien , Néerlandais -
Operating Instructions Deltapilot S.
Partial mounting of the housing.
Instructions condensées (KA)02/98Allemand , Anglais , Espagnol , fr , Italien , Néerlandais -
Harting plug HAN7D
Installation instruction
Cerabar M/S, Deltabar M/S, Deltapilot M/S
Instructions de montage (EA) -
Stainless steel housing F8
Installation instruction
Deltapilot S
Instructions de montage (EA) -
Pressure adapter
Installation instruction
Deltapilot M, Deltapilot S, Waterpilot
Instructions de montage (EA) -
Mounting set for Deltapilot M, Deltapilot S
Installation instruction
Deltapilot M, Deltapilot S
Instructions de montage (EA) -
Deltapilot S DB50, DB50L, DB51, DB52, DB53
FOUNDATION Fieldbus
II 1/2 G, II 2 G EEx ia IIC T6...T4
PTB 98 ATEX 2134 (ATEX)Conseils de sécurité ATEX (XA) -
Safety Instructions
Deltapilot S DB50, DB50L, DB51, DB52, DB53
PROFIBUS PA
II 1/2 G, II 2 G EEx ia IIC T6...T4
PTB 98 ATEX 2134 (ATEX)Conseils de sécurité ATEX (XA) -
Deltapilot S DB50, DB50L, DB51, DB52, DB53
Approval No.: EG 02 004-a
ATEX II 3 G Protection: EEx nA II T6
PFM, 4...20 mA HART, PROFIBUS PA, FOUNDATION FieldbusConseils de sécurité ATEX (XA) -
Safety Instructions
Deltapilot S DB50, DB50L, DB51, DB52, DB53
PFM, 4...20 mA
II 1/2 G, II 2 G EEx ia IIC T6...T4
PTB 98 ATEX 2094 (ATEX)Conseils de sécurité ATEX (XA) -
Deltapilot S DB50, DB50L, DB51, DB52
Z-65.11-246 (DIBt)
Certificats (ZE) -
Deltapilot S DB50, DB50L, DB51, DB52
Z-65.11-128 (DIBt)
Certificats (ZE) -
Deltapilot S DB50(L), DB51, DB52, FEB17(P), FMC470Z/671Z, FMX570,
FMB672Z, SIF100/110, HTA470Z
Z-65.11-29 (DIBt)
Certificats (ZE) -
Deltapilot S DB50, DB50L, DB51, DB52, DB53
CSA
Drawing No.: 960373-2024 A
Drawing Type: Control Drawing
FOUNDATION FieldbusCertificats FM/CSA (ZD) -
Deltapilot S DB50, DB50L, DB51, DB52, DB53
FM
Drawing No.: 960373-1021 B
Drawing Type: Control Drawing
PROFIBUS PACertificats FM/CSA (ZD) -
Deltapilot S DB50, DB50L, DB51, DB52, DB53
CSA
Drawing No.: 960373-2021 B
Drawing Type: Control Drawing
PROFIBUS PACertificats FM/CSA (ZD) -
Deltapilot S DB50, DB50L, DB51, DB52, DB53
FM
Drawing No.: 960373-1024 B
Drawing Type: Control Drawing
FOUNDATION FieldbusCertificats FM/CSA (ZD) -
Interoperability Statement: Deltapilot S, FOUNDATION fieldbus
Endress+Hauser field device has been tested with Rockwell Automation
Integrated Architecture-based host system Allen-Bradley ControlLogix.
Deltapilot S, FOUNDATION fieldbus Level Transmitter, Device Revision: 1,
DD Revision: 2, Device ID: 0x100B, Software Revision: 1.0Information spécifique (SD) -
Control Engineering marzec 2006
Akredytowana kalibracja przetworników ci&
347;nienia i ró
&
380;nicy ci&
347;nie&
324;Publications (PU)09/08Polonais -
Nap&
281;dy i Sterowanie grudzie&
324; 2007
Nowa generacja zaawansowanych
rejestratorów Endress+Hauser Memograph MPublications (PU)08/09Polonais -
Napędy i Sterowanie styczeń 2006
Wykorzystanie pomiarów radiometrycznych na obiektach automatyki
przemys
łowejPublications (PU)08/09Polonais -
Napędy i Sterowanie styczeń 2007
Deltapilot S - unikatowa, sprawdzona technologia w hydrostatycznych
pomiarach poziomuPublications (PU)08/09Polonais -
Nap&
281;dy i Sterowanie marzec 2008
Technologie czujników ci&
347;nienia Endress+HauserPublications (PU)03/08Polonais -
Geräteintegration in eine Biodiesel-Anlage. Fallbeispiel Engineering
Integration verschiedener Messgeräte und Aktoren in der Campa
Biodiesel-Anlage, Ochsenfurt, Deutschland. Die Campa AG mit Sitz in Oc
hsenfurt bei
Würzburg zählt bei Produktion sowie im
internationalem Handel und Vertrieb zu
den innovativen Pionierunternehmender
jungen Biokraftstoffindustrie.Etudes de cas (CS)04/07Allemand -
Device integration into a biodiesel plant
Case Study Engineering
Integration of various measurement devices and actuators at Campa
Biodiesel Plant, Ochsenfurt, GermanyEtudes de cas (CS)04/07Anglais -
GSD Single, GSD_EH_PA_LE_Deltapilot_0x1503_V02_00_PALIB, 14.04.2014 (Leve
l, Deltapilot S, 0x1503)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)2.00.00Language neutral -
GSD Single, GSD_EH_PA_LE_Deltapilot_0x1503_V01_00_PALIB, 14.04.2014 (Leve
l, Deltapilot S, 0x1503)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDD Single, PDM_PA_LE_DeltapilotS_0x1503_0x03_0x01, 07.01.2019 (Level, Deltapilot S, 0x1503)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_LE_DeltapilotS_0x100Ba_0x01_0x01_ITK4_01, 10.11.2016 (L
evel, Deltapilot S, 0x100B
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 4.01Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_LE_DeltapilotS_0x1503_0x02_0x01, 07.01.2019 (Level, Deltapilot S, 0x1503)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_LE_DeltapilotS_0x000B_0x02_0x02, 07.11.2018 (Level, Deltapilot S, 0x000B)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_LE_DeltapilotS_0x100Ba_0x01_0x02_ITK4_60, 10.11.2016 (L
evel, Deltapilot S, 0x100B
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 4.60Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, DeltapilotS_FEB24_PA_V2_0___V2_2, 20.10.2020 (Level, Deltapilot S, 0x1503)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, DeltapilotS_FEB24_PA_V1_0___V1_1, 20.10.2020 (Level, Deltapilot S, 0x1503)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, DeltapilotS_FEB24_PA_V1_3, 20.10.2020 (Level, Deltapilot S, 0x1503)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, DeltapilotS_DB5x_V2_0, 23.10.2020 (Level, Deltapilot S, 0x000B)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, DeltapilotS_DB5x_V1_x, 23.10.2020 (Level, Deltapilot S, 0x000B)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
Faceplate Library, PRM_FF_Package_Level_1_05_00, 29.05.2018 (Level)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.02, R3.12Faceplate1.05.00Language neutral -
Product Family: Deltapilot S
Code produit: DB51A-, DB51-, DB52-, DB53-, DB52A-, DB50A-, DB50L-, DB50S-, DB53A-, DB50-
Région/Pays: International
Organisme d\'accréditation: PNO, Profibus
Version de software: PROFILE 3.0Fieldbus ConformanceAnglais
Accessoires / pièces de rechange
-
-
Order code
Arrêt de production pièces détachées
-
Order code
-
-
-
Nr 11 Order code 910127-0001
Gasket 34x39x0.2, PTFE
-
-
-
Order code 52006263
Embase connect. M12 droit 4b.125V-4A
Corps PA, écrou CuZn Raccordement à confectionner Utilisation : connecteur de boîtier M12
-
-
-
Nr 21 Order code 014850-0000
O-ring 73,0 x 3,0 EPDM 60 +PTFE
Usage: housing cover F6/F10, terminal compartment cover T3.
-
-
-
Nr 20 Order code 52002593
Couvercle F6 haut aluminium + joint
EPDM 73,0 x 3,0 Utilisation: boîtier F6 aluminium
-
Nr 20 Order code 52002594
Couvercle F10 haut PBT + joint
Joint torique VMQ Utilisation: boîtier F10 Polyester
-
-
-
Order code 917755-0000
Protection cover, PFA
Usage: DB4x/DB5x, FMX165, FMX167/FMX21 42mm.
-
-
-
Nr 51 Order code 013543-0001
O-ring 28,17 x 3,53 EPDM 70 +PTFE
-
-
-
Nr 53 Order code 535555-1100
Mounting set CONTITE FKM sensor Viton
Consists of: PC centering ring, retaining ring. Membrane protection cap. O-ring FKM Viton. Usage: FMB51/52/53. DB50/50A/50L/50S/51/51A/52/52A/53/53A.
-
-
-
Order code 52024469
Manchon à souder G1-1/2, inox 316L
Montage raccordement process G1-1/2 Matériau: inox 316L Installation correcte avec mannequin Utilisation: PMC71, PMP71, PMP75, FMB50/FMB51/FMB52, FMB70, PMC51, PMP51/PMP55.
-
Order code 52024470
Manchon à souder G1-1/2, 316L, 3.1
Montage raccordement process G1-1/2 Matériau: inox 316L. Certificat matière selon EN10204-3.1 Utilisation: PMC71, PMP71, PMP75, FMB50/51/52, FMB70, PMC51, PMP51, PMP55.
-
Order code 52024471
Mannequin de soudage G1-1/2
Matériau: laiton Pour éviter toute déformation lors du soudage du manchon à souder 52024469 / 52024470.
-
Order code 942262-0000
Weather protection cover F6/F10
Material: PA. Usage: FTL70/FTL71.
-
-
Prédécesseur
-
Successeur
-
Produits simples
- Facile à sélectionner, à installer et à utiliser
Excellence technique
Simplicité
-
Produits standard
- Fiable, robuste et effort de maintenance réduit
Excellence technique
Simplicité
-
Produits haut de gamme
- Hautement fonctionnel et pratique
Excellence technique
Simplicité
-
Produits spécialisés
- Conçu pour les applications exigeantes
Excellence technique
Simplicité
Variable
FLEX selections Excellence technique Simplicité - F
- L
- E
- X
Fundamental selection
Parfait pour les applications de base
Excellence technique Simplicité - F
- L
- E
- X
Lean selection
Performances optimales pour piloter les applications standards
Excellence technique Simplicité - F
- L
- E
- X
Extended selection
Fonctionnalités avancées pour maximiser vos process
Excellence technique Simplicité - F
- L
- E
- X
Xpert selection
Performances exceptionnelles pour applications exigeantes
Excellence technique Simplicité Variable
-